EI-5030 IM Channelized Pedestrian and Luggage Radiation and Identification Monitoring System

Description

Product Instruction
EI-5030M is a radioactive material monitoring equipment specifically for entrance and exit of large event venues and entry and exit security lanes. It uses a highly sensitive gamma detector and a newly designed spectral analysis algorithm, it combines dose rate measurement, nuclide identification and neutron measurement technologies to quickly and effectively screen the radioactivity of passing pedestrians and the accompanying luggage to determine whether radioactive substances are carried, effectively providing security against illegal carriage of radioactive substances.
 
Functional features
Modular detector design with 5mm thick lead shielding on the non-detecting side of the gamma detector
HD camera with real-time pictorial display of pedestrians passing, automatic or manual capture
Automatic radiation alarm, automatic alarm data storage, automatic storage of measurement logs
Real-time display of gamma count rate, dose rate and real-time nuclide identification results; real-time display of neutron count rate
Environmental adaptability using natural K-40 automatic spectrum stabilization technology
Real-time dynamic background monitoring to ensure that alarm thresholds are dynamically updated with background fluctuations
Audible and visual alarm function, artificially controllable
Multi-point deployment and remote operation possible
ANSI-compatible nuclide library, including special nuclear materials, industrial nuclides, natural radionuclides and user-defined nuclides
Complies with GB/T 31836-2015, ANSI N42.42 and other relevant standards
 
Application areas
Customs gates, airports, ports, environmental agencies, nuclear power stations, etc
 
Technical specifications
Physical properties
Detector type Gamma: 2 x 2L NaI(Tl) scintillation crystals; Neutron: 3He positive counter tube (optional)
Monitoring area Height: 2.1m, Width: 1.5m
Energy range Gamma: 20keV ~ 3MeV; Neutron: 0.025eV ~ 14MeV (optional)
Sensitivity: Gamma: 0.04μSv/h increase, alarm within 1 second (background level 0.2μSv/h)
Neutrons: 2 x 104/s of 252Cf passing through the detection area at 1.2m/s, alarm rate > 98%
Shielding method 5mm thick lead shielding substrate for non-detecting surfaces
False alarm rate ≤ 0.1%
Detection objects Pedestrians and objects Standard passing speed for pedestrians :1.2m/s
Electrical characteristics
Power supply method AC 220V±10%, 50Hz±10%; Communication methods RJ45
Mechanical properties
Machine size 2400H×2000W×600D(mm); Weight 230kg
Environmental characteristics
Operating temperature 0 to 40 ; Operating humidity ≤ 95% (no condensing)